Aller au contenu principal
Accueil

Dedicated to discovery

  • À propos d'ELGA
    • À propos d'ELGA
    • Carrières
    • Événements
  • Assistance
    • Aménagement du laboratoire
  • Contact
  • Ultrapure water
  • EN
  • DE
  • ES
  • IT
  • PT
  • EN-US
Accueil
  • Produits
    • PURELAB
      • PURELAB® Dispenser
      • PURELAB® Flex
      • PURELAB® Quest
      • PURELAB® Pharma Compliance
      • PURELAB® Chorus 1 Complete
      • PURELAB® Chorus 1
      • PURELAB® Chorus 2
      • PURELAB® Chorus 3
      • PURELAB® Chorus 2 +
    • CENTRA
      • CENTRA® R60/120
      • CENTRA® R200
      • CENTRA® RDS
    • MEDICA
      • MEDICA® 150
      • MEDICA® 7/15
      • MEDICA® BIOX 2024
      • MEDICA® Pro-R & Pro-RE
      • MEDICA® R200
      • MEDICA® EDI 15/30
      • MEDICA® Pro-LPS
      • MEDICA® Pro EDI 60/120
      • MEDICA® BIOX
      • MEDICA BIOX-2
      • Hubgrade
    • BIOPURE
      • BIOPURE® 300/600
    • PURENERGY 30 - Electrolyser Water Supply
    • Gamme complète des produits ELGA
  • Applications
    • Analytical Technologies
      • Spectroscopie atomique
      • Électrochimie
      • Chromatography
        • Chromatographie en phase gazeuse
        • High Performance Liquid Chromatography (HPLC)
        • Chromatographie en phase liquide
      • Spectrométrie de masse
      • Spectrophotométrie
    • Biological & Life Sciences
      • Cultures cellulaires
      • Génétique
      • Analyse microbiologique
      • Immunochimie
    • Biochimie clinique
    • All Applications
  • Technologies
    • Charbon actif
    • Électrodéionisation (EDI)
    • Filtration
    • Échange ionique
    • PureSure
    • Osmose inverse
    • Ultraviolet
    • All Technologies
  • Resources
    • All Resources
    • Blog
    • Études de cas
    • Guides et livres blancs
    • Impuretés dans l'eau
      • Exigences générales d'un laboratoire en matière d'eau
      • Gaz dissous
      • Composés inorganiques
      • Micro-organismes et bactéries
      • Composés organiques
      • Particules
  • Où acheter ?
  • Contact
Home
  • Contact
  • Produits
    • PURELAB
      • PURELAB® Dispenser
      • PURELAB® Flex
      • PURELAB® Quest
      • PURELAB® Pharma Compliance
      • PURELAB® Chorus 1 Complete
      • PURELAB® Chorus 1
      • PURELAB® Chorus 2
      • PURELAB® Chorus 3
      • PURELAB® Chorus 2 +
    • CENTRA
      • CENTRA® R60/120
      • CENTRA® R200
      • CENTRA® RDS
    • MEDICA
      • MEDICA® 150
      • MEDICA® 7/15
      • MEDICA® BIOX 2024
      • MEDICA® Pro-R & Pro-RE
      • MEDICA® R200
      • MEDICA® EDI 15/30
      • MEDICA® Pro-LPS
      • MEDICA® Pro EDI 60/120
      • MEDICA® BIOX
      • MEDICA BIOX-2
      • Hubgrade
    • BIOPURE
      • BIOPURE® 300/600
    • PURENERGY 30 - Electrolyser Water Supply
    • Gamme complète des produits ELGA
  • Applications
    • Analytical Technologies
      • Spectroscopie atomique
      • Électrochimie
      • Chromatography
        • Chromatographie en phase gazeuse
        • High Performance Liquid Chromatography (HPLC)
        • Chromatographie en phase liquide
          • High Performance Liquid Chromatography
      • Spectrométrie de masse
      • Spectrophotométrie
    • Biological & Life Sciences
      • Cultures cellulaires
      • Génétique
      • Analyse microbiologique
      • Immunochimie
    • Biochimie clinique
    • All Applications
  • Technologies
    • Charbon actif
    • Électrodéionisation (EDI)
    • Filtration
    • Échange ionique
    • PureSure
    • Osmose inverse
    • Ultraviolet
    • All Technologies
  • Resources
    • All Resources
    • Blog
    • Études de cas
    • Guides et livres blancs
    • Impuretés dans l'eau
      • Exigences générales d'un laboratoire en matière d'eau
      • Gaz dissous
      • Composés inorganiques
      • Micro-organismes et bactéries
      • Composés organiques
      • Particules
  • Où acheter ?
  • Contact
  • À propos d'ELGA
    • À propos d'ELGA
    • Carrières
    • Événements
  • Assistance
    • Aménagement du laboratoire
  • Contact
  • Ultrapure water
  • EN
  • DE
  • ES
  • IT
  • PT
  • EN-US
  • Politique relative à la confidentialité
  • Conditions générales
  • Conformité juridique mondiale
  • Brevets
  • Trademarks
  • Impressum
  • How To Select The Right Water Purity For Your Lab Applications
Water Purity

How To Select The Right Water Purity For Your Lab Applications

12 juin 2026
- by lorraine ocloo

Pure Water Is Used Almost Everywhere In The Lab

Water is used almost everywhere in the lab, from being a key reagent in your day-to-day experiments, tests, and assays, to performing those "behind the scenes" functions like autoclaving, glassware cleaning, media preparation, and water bath setup. But not all lab water is created equal. Different techniques demand different levels of purity, and using the wrong grade can introduce ions, organics, or microbial contaminants that bias results, damage instruments, or invalidate an entire run.

Most lab water falls into three grades defined by ASTM D1193 and ISO 3696. Type I (ultrapure) water is required for the most sensitive applications (HPLC, UHPLC, LC-MS, GC-MS, ICP-MS, ICP-OES, atomic absorption spectroscopy, cell and tissue culture, PCR, qPCR, and next-generation sequencing) where trace contaminants would interfere with detection or biological activity. Type II (pure) water is the right choice for buffer preparation, ELISA and immunochemistry workflows, microbiology, electrochemistry, and spectrophotometry. Type III (RO) water is sufficient for glassware washing, autoclave feed, and media prep, and is also commonly used as feedwater for Type I polishing systems. Clinical chemistry analyzers require CLRW-grade water.

Knowing exactly which type of water purity your particular application requires can take time to go away and research — time that could be better spent at the bench. To help you make the most of your valuable time, we've assembled this quick reference table enabling you to easily match your application with the required water quality.

And for more information about the different types of water, check out this guide here too.

Check Out Our Quick Reference Guide To Match Your Laboratory Application And Water Purity

Technique

Application sensitivity required

Resistivity (MΩ-cm)*

TOC (ppb)

Filter (μm)

Bacteria (CFU/ml)

Endotoxins (EU/ml)

Nucleases

Water grade

Water type

Feed to still

Low

>0.05

<500

NA

NA

NA

NA

Primary

III

Feed to ultra pure water system

General

>0.05

<50

NA

NA

NA

NA

Primary

II+

High

>1

<10

<0.2

<1

NA

NA

Ultra pure

I

General chemistry

General

>1

<50

<0.2

<10

NA

NA

General lab

II+

Glassware washing

General

>1

<50

<0.2

<10

NA

NA

General lab

II+

High

>18

<10

<0.2

<1

NA

NA

Ultra pure

I

Media preparation

General

>1

<50

<0.2

<1

NA

NA

General lab

II+

Solution preparation and dilutions

General

>1

<50

<0.2

<1

NA

NA

General lab

II+

High

>18

<10

<0.2

<1

NA

NA

Ultra pure

I

Steam generation

General

>1

<50

<0.2

<1

NA

NA

General lab

I

Bacterial cell culture

General

>1

<50

<0.2

<1

NA

NA

General lab

I

Clinical biochemistry

USP/EP

>2

<500

<0.2

<1

NA

NA

General lab

I

CLSI

>10

<500

<0.2

<1

NA

NA

General lab

I

Electrophoresis

High

>18

<10

UF

<1

<0.005

ND

Apyrogenic Ultra pure

I

Electrophysiology

General

>1

<50

<0.2

<1

NA

NA

General lab

I

ELISA

General

>1

<50

<0.2

<1

NA

NA

General lab

I

Endotoxin analysis

Standard

>1

<50

<0.2

<1

<0.05

NA

Apyrogenic General lab

I

High

>18

<10

UF

<1

<0.002

ND

Apyrogenic Ultra pure

I

Histology

General

>1

<50

<0.2

<1

NA

NA

General lab

I

Hydroponics

General

>1

<50

<0.2

<1

NA

NA

General lab

I

Immunocytochemistry

High

>18

<10

UF

<1

<0.002

ND

Apyrogenic Ultra pure

I

Mammalian cell culture

High

>18

<10

UF

<1

<0.002

ND

Apyrogenic Ultra pure

I

Microbiological analysis

General

>1

<50

<0.2

<1

NA

NA

General lab

I

Molecular biology

High

>18

<10

UF

<1

<0.002

ND

Apyrogenic Ultra pure

I

Monoclonal antibody research

General

>1

<50

<0.2

<1

NA

NA

General lab

I

High

>18

<10

UF

<1

<0.002

ND

Ultra pure

I

Plant tissue culture

High

>18

<10

UF

<1

<0.002

ND

Apyrogenic Ultra pure

I

Radioimmunoassay

General

>1

<50

<0.2

<1

NA

NA

General lab

I

Electrochemistry

General

>5

<50

<0.2

NA

NA

NA

General lab

II

High

>18

<10

<0.2

<1

NA

NA

Ultra pure

I

Flame-AAS

General

>5

<500

<0.2

NA

NA

NA

General lab

II

GC-MS

High

>18

<3

<0.2

<1

NA

NA

Ultra pure

I

GF-AAS

High

18.2

<10

<0.2

<10

NA

NA

Ultra pure

I+

HPLC

General

>1

<50

<0.2

<1

NA

NA

General lab

I

High

>18

<3

<0.2

<1

NA

NA

Ultra pure

I

ICP-AES

General

>5

<50

<0.2

NA

NA

NA

General lab

II

High

>18

<10

<0.2

<1

NA

NA

Ultrapure

I

ICP-MS

General

>10

<50

<0.2

<10

NA

NA

General lab

II+

High

18.2

<10

<0.2

<1

NA

NA

Ultra pure

I

Ion chromatography

General

>5

<50

<0.2

<10

NA

NA

General lab

II+

High

18.2

<10

<0.2

<1

NA

NA

Ultrapure

I

Solid phase extraction

General

>1

<50

<0.2

<10

NA

NA

General lab

II+

High

>18

<3

<0.2

<1

NA

NA

Ultra pure

I

Spectrophotometry

General

>1

<50

<0.2

<10

NA

NA

General lab

II+

High

>18

<10

<0.2

<1

NA

NA

Ultra pure

I+

TOC analsys

General

>1

<50

<0.2

<10

NA

NA

General lab

II+

High

>18

<3

<0.2

<1

NA

NA

Ultra pure

I+

Trace metal detection

General

>5

<50

<0.2

<10

NA

NA

General lab

II+

High

18.2

<10

<0.2

<1

NA

NA

Ultra pure

I+

Don’t see your application listed?

Contact a Lab Water Specialist at one of our Approved Business Partners for assistance - see below.

Find an Approved Partner

 

 

Find the right ELGA LabWater product for your application needs

PURELAB® Quest
The only purifier on the market that dispenses all 3 types of science ready water from a compact, economical, and easy to use system! - Type 1, 2, and 3 Water
View
PURELAB® Chorus 2
When Type 2 water is all you need, then PURELAB Chorus 2 (RO/DI) is the reliable and flexible solution, providing Type 2 water at 10 M.cm, for needs between 10 and 480 liters per day.
View
PURELAB® Chorus 3
The PURELAB Chorus 3 is a modular, Type 3 water purification system with high-capacity storage for general laboratory applications. Ideal for autoclaves, glasswashers, and buffer preparation, where consistent, reliable water is essential.
View

FAQs

What type of water do I need for HPLC?

HPLC requires Type I ultrapure water to avoid contaminant interference that can compromise separation and quantification. ELGA's ultrapure water meets 18.2 MΩ·cm resistivity at 25 °C, TOC <10 ppb, and bacterial counts <1 CFU/mL, ensuring the purity needed to protect chromatographic accuracy and reproducibility. PURELAB Chorus 1, flex, and Quest systems are designed for HPLC, LC-MS, and GC-MS workflows. Find the right water purification system for your application or speak to an expert.

What water purity is required for cell and tissue culture?

Mammalian cell and tissue culture requires Type I ultrapure water with bacterial endotoxins below 0.03 EU/mL and undetectable levels of nucleases and proteases. Trace contaminants can inhibit cell growth, alter gene expression, and compromise reproducibility between passages. ELGA's ultrapure systems are designed for mammalian cell culture, protecting cell viability and experimental reproducibility from passage to passage. Find the right water purification system for your application or speak to an expert.

What type of water should I use for PCR and molecular biology?

PCR and molecular biology applications typically require Type I ultrapure water free of nucleases, proteases, and endotoxins, since even trace contamination can degrade nucleic acids or inhibit amplification. ELGA's ultrapure water delivers 18.2 MΩ·cm resistivity at 25 °C, TOC <10 ppb, and undetectable levels of DNases and RNases. Find the right water purification system for your application or speak to an expert.

Can I use Type II water instead of Type I?

Type II water is not a substitute for Type I in applications where trace contaminants affect results, such as HPLC, LC-MS, PCR, or cell culture. Using Type II water in place of Type I increases the risk of background interference, baseline drift, and compromised reproducibility. Type II is suitable for less sensitive applications, including buffer preparation, microbiological analysis, electrochemistry, and spectrophotometry.

What happens if I use water that isn't pure enough for my application?

Using water below the required purity grade puts your results at risk. Contaminants can cause baseline drift, ghost peaks, failed reactions, impaired cell growth, and inconsistent data across runs, leading to wasted reagents, samples, consumables, and time. Matching water purity to the application is the simplest way to protect data integrity. Find the right water purification system for your application or speak to an expert.

 

  • Sales Enquiry
  • Request A Quote
  • Technical Support
  • Book A Demo
  • Trouver un partenaire approuvé

Request a quote

Chez ELGA LabWater, nous proposons des offres intéressantes et des nouvelles sur nos produits et services dont nous espérons que vous aimeriez entendre parler. Nous utiliserons vos informations pour prédire ce qui pourrait vous intéresser. Nous traiterons vos données avec respect et vous trouverez les détails dans notre Privacy Policy.

ELGA LabWater travaille avec un réseau de partenaires agréés. Afin de répondre à vos questions ou demandes de renseignements, nous pouvons transmettre vos coordonnées à un Partenaire Agréé, qui pourra vous contacter directement.

J'aimerais recevoir des mises à jour d'ELGA LabWater et des partenaires agréés ELGA en fonction de mes coordonnées.

From setup to servicing, your local team has you covered. Every team is fully trained on all ELGA systems to support your lab's complete water purification needs. For any technical queries, please contact [email protected]

Book A Demo

Chez ELGA LabWater, nous proposons des offres intéressantes et des nouvelles sur nos produits et services dont nous espérons que vous aimeriez entendre parler. Nous utiliserons vos informations pour prédire ce qui pourrait vous intéresser. Nous traiterons vos données avec respect et vous trouverez les détails dans notre Privacy Policy.

ELGA LabWater travaille avec un réseau de partenaires agréés. Afin de répondre à vos questions ou demandes de renseignements, nous pouvons transmettre vos coordonnées à un Partenaire Agréé, qui pourra vous contacter directement.

Our team typically responds within 1 business day. By submitting, you agree to ELGA’s privacy policy

Technical Support

Chez ELGA LabWater, nous proposons des offres intéressantes et des nouvelles sur nos produits et services dont nous espérons que vous aimeriez entendre parler. Nous utiliserons vos informations pour prédire ce qui pourrait vous intéresser. Nous traiterons vos données avec respect et vous trouverez les détails dans notre Privacy Policy.

ELGA LabWater travaille avec un réseau de partenaires agréés. Afin de répondre à vos questions ou demandes de renseignements, nous pouvons transmettre vos coordonnées à un Partenaire Agréé, qui pourra vous contacter directement.

Our team typically responds within 1 business day. By submitting, you agree to ELGA’s privacy policy

Sales Enquiry

Chez ELGA LabWater, nous proposons des offres intéressantes et des nouvelles sur nos produits et services dont nous espérons que vous aimeriez entendre parler. Nous utiliserons vos informations pour prédire ce qui pourrait vous intéresser. Nous traiterons vos données avec respect et vous trouverez les détails dans notre Privacy Policy.

ELGA LabWater travaille avec un réseau de partenaires agréés. Afin de répondre à vos questions ou demandes de renseignements, nous pouvons transmettre vos coordonnées à un Partenaire Agréé, qui pourra vous contacter directement.

J'aimerais recevoir des mises à jour d'ELGA LabWater et des partenaires agréés ELGA en fonction de mes coordonnées.

Call us

Can't find what you are looking for?

Support Number
+44 (0)20 3567 7300
United Kingdom Sales
+44 (0)1628 879 704
United States of America Sales
+1 877-315-3542
France Sales
+33 1 40 83 65 00
China Sales
+86 400-616-8882

 

Siège social ELGA LabWater

Lane End Business Park
Lane End, High Wycombe
HP14
3BY Royaume-Uni
T : +44 (0) 203 567 7300 - Fax
 : +44 (0) 203 567 7205

Études de cas

  • Diagnostics Abbott
  • Diagnostics médicaux DASA
  • Institut médical NeoDIN
  • Fondation North Staffordshire NHS Trust
  • Lycée professionnel d'Olsberg

Ressources

  • En savoir plus sur l'eau ultra-pure
  • Guides et livres blancs
  • Technologies de purification
  • Applications
  • Impuretés dans l'eau
  • Latest Blog
  • What is Total Organic Carbon (TOC)?
  • What is Clinical Laboratory Reagent Water (CLSI)?
  • Water Purity - Different Types of Pure Water

© VWS (UK) Ltd. exerçant sous le nom ELGA LabWater.2026-Tous les droits sont réservés.
ELGA est la marque mondiale d'eau de laboratoire de Veolia.

  • Politique relative à la confidentialité
  • Conditions générales
  • Conformité juridique mondiale
  • Brevets
  • Trademarks
  • Impressum
  • Langue
    • Deutsch
    • English
    • Español
    • Français
    • Italiano
    • Português
    • 日本語
    • 中文
  • Autres sites Veolia
    • Veolia
    • Veolia Foundation
    • Veolia Water Technologies
Elga Veolia
TOP

© 2017 ELGA Veolia